This includes company names of contractors. This includes memes.īlatant incorrect information or unsafe advice will result with a ban.ĭO NOT post any personal information. Low quality posts will be removed at the discretion of the mod team. Rules Generalĭon't be a dick, and adhere to the reddiquette If you are looking for DIY or general help please visit /r/askelectricians Pre-Apprentices start here before posting Help your fellow Redditors crack the electrical code. Talk shop, show off pictures of your work, and ask code related questions. Reddit's International Electrical Worker CommunityĪka The Great Reddit Council of Electricians In this photo, have a piece of paper with your username and date written on it. To get verified, send a photo to the mods that has your certificate/seal/card. Users with have verified their qualifications with the Mods Then message the mods with the country you are from. 16, 1998).To add your country's flag to your flair, you must select a title from the drop down menu. Dennis Vance, Using electrical tape to repair minor damage to the outer jacket of an extension cord (Dec. For information on Minnesota's Electrical standard and its enforcement, we suggest that you contact: James Krueger, Compliance Directorġ See Letter to Mr. Although some of Minnesota's standards are different, both its standards and interpretations must be at least as effective as Federal OSHA's. Under this plan, the Minnesota Department of Labor promulgates and enforces occupational safety and health standards under authority of State law, and posts them on its website at. 1 As you may be aware, the State of Minnesota operates its own occupational safety and health program under a plan approved by Federal OSHA. For example, you are precluded from using a repaired cord if the repair changes the cord's original flexibility. (c) With respect to custom-made equipment or related installations which are designed, fabricated for, and intended for use by a particular customer, if it is determined to be safe for its intended use by its manufacturer on the basis of test data which the employer keeps and makes available for inspection to the Assistant Secretary and his authorized representatives.Īssuming the extension cord you are repairing was initially "acceptable," §1926.403(a) precludes you from using a repaired cord if the cord is significantly altered as a result of the repair. (b) With respect to an installation or equipment of a kind which no qualified testing laboratory accepts, certifies, lists, labels, or determines to be safe, if it is inspected or tested by another Federal agency, or by a State, municipal, or other local authority responsible for enforcing occupational safety provisions of the National Electrical Code, and found in compliance with those provisions or (a) If it is accepted, or certified, or listed, or labeled, or otherwise determined to be safe by a qualified testing laboratory capable of determining the suitability of materials and equipment for installation and use in accordance with this standard or Section 1926.449 defines "acceptable" as: An installation or equipment is acceptable to the Assistant Secretary of Labor, and approved within the meaning of this subpart K: The definition of "acceptable" indicates what is acceptable to the Assistant Secretary of Labor, and therefore approved within the meaning of this subpart. The authority enforcing this subpart is the Assistant Secretary of Labor for the Occupational Safety and Health. 12 or larger.Īdditionally, 1926.403(a) requires all electrical conductors used by employers on a construction site to be "approved." Section 1926.449 defines "approved" as: Acceptable to the authority enforcing this subpart. This standard permits you to repair an extension cord, under the conditions set forth, provided the cord is a flexible cord that is No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced. Question: Under what circumstances may an employer located in Minnesota repair a damaged extension cord under, Subpart K?Īnswer: Paragraph 1926.405(g)(2)(iii) provides: Flexible cords shall be used only in continuous lengths without splice or tap. Re: Whether an employer can repair an extension cord under, Subpart K.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |